Rockwell Automation 1756-EN3TR ControlLogix EtherNet/IP Communication Module Installation Instructions User Manual

Page 23

Advertising
background image

23

Publication

1756-IN612B-EN-P - December 2009

Immunity, radiated RF

IEC 61000-4-3

10V/m with 1 kHz sine-wave 80%AM from
80…2000 MHz

10V/m with 200 Hz 50% Pulse 100%AM at
900 MHz

10V/m with 200 Hz 50% Pulse 100%AM at
1890 MHz

3V/m with 1 kHz sine-wave 80%AM from
2000…2700 MHz

Immunity, EFT/B

IEC 61000-4-4

±3 kV at 5 kHz on Ethernet port

Immunity, surge transient

IEC 61000-4-5

±2 kV line-earth(CM) on Ethernet port

Immunity, conducted RF

IEC 61000-4-6

10V rms with 1 kHz sine-wave 80%AM
from 150 kHz…80 MHz

Certifications - 1756-EN2TR and 1756-EN3TR

Certification

Value

When product is marked. See the Product Certification link at

http://www.ab.com

for Declarations of Conformity,

Certificates, and other certification details

c-UL-us

UL Listed Industrial Control Equipment, certified for US and Canada.
See UL File E65584.
UL Listed for Class I, Division 2 Group A,B,C,D Hazardous Locations,
certified for U.S. and Canada. See UL File E194810.

FM

FM Approved Equipment for use in Class I Division 2 Group A,B,C,D
Hazardous Locations

Environmental Specifications - 1756-EN2TR and 1756-EN3TR

Attribute

Value

Advertising