Connecting the input wiring, Connecting the output wiring – Rockwell Automation 1792-IB8XOB8PLP INSTL INSTR ARMORBLOCK LP 8/8 User Manual
Page 5

ArmorBlock-LP 8 Input/8 Output Module
5
Publication 1792-5.8 – December 1997
Seven micro caps are included with your module. Use these caps to
cover and seal unused ports. Pinout diagrams for the connectors are
shown below.
!
ATTENTION: Make sure all connectors are securely
tightened to properly seal the connections against leaks and
maintain IP67 requirements.
Connecting the Input Wiring
Connect input wiring to the micro-connectors which screw into mating
connectors on the front of the block.
1
2
3
4
I/O Input Micro-Connector
Pin 1 = Sensor Source Voltage Positive
Pin 2 = Signal B
Pin 3 = Negative/Return
Pin 4 = Signal A
(View into socket)
5
Pin 5 = Ground
Connecting the Output Wiring
Connect output wiring to the micro-connectors which screw into mating
connectors on the front of the block.
1
2
3
4
I/O Output Micro-Connector
Pin 1 = No connection
Pin 2 = Signal B
Pin 3 = Negative/Return
Pin 4 = Signal A
(View into socket)
5
Pin 5 = Ground