Use the DeviceNet Test Application to Verify the Configuration 6-3

Publication 1784-IN004E-EN-P - April 2005

Create a View

To go online and create a view, follow these steps:

1. From the Setup menu, select Create View.... You see the View Creation Parameters

screen.

2. Select the port name corresponding to the port for which you are creating the view.

3. Select the message type (input, output, or input/output) that you want to use for the

view you are creating.

4. Select the privilege (read only, read/write) that you want to use for the view that you

are creating.

5. If you want to use the Watchdog timer for the view you are creating, check the

Enabled checkbox and enter the watchdog timeout value (in milliseconds) that you
want to use.

6. Click OK. You see a dialog box that tells you that the operation was successful.