1769-IQ32
The following I/O memory mapping lets you configure the 1769-IQ32 module.
Input Data File
For each input module, slot
x, word 0 in the input data file contains the current
state of the field input points.
1769-IQ32T
The following I/O memory mapping lets you configure the 1769-IQ32T
module.
Input Data File
For each input module, slot
x, words 0 and 1 in the input data file contain the
current state of the field input points.
Filter Time
(1)
(1) Filter Time: Word 0, the Filter Time configures the ON to OFF
and OFF to ON hardware delay times for each input group.
Bit Setting
2.0 msec
0010
1.0 msec
0011
0.5 msec
0100
0.1 msec
0101
0.0 msec
0110
Wo
rd
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
r
(1)
(1) r = read.
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
1
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
Wo
rd
Bit Position
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
r
(1)
(1) r = read.
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
1
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r
r