Rockwell Automation 1756-CNB ControlLogix ControlNet Bridge Module, Series E Installation Instructions User Manual

Page 32

Advertising
background image

32 ControlLogix ControlNet Interface Module

Publication

1756-IN604A-EN-P - February 2006

ESD immunity

IEC 61000-4-2:

6 kV contact discharges

8 kV air discharges

Radiated RF immunity
Series E

IEC 61000-4-3:

10 V/m with 1 kHz sine-wave 80%AM from 30…2000 MHz

10 V/m with 200 Hz 50% Pulse 100%AM at 900 MHz

10 V/m with 200 Hz 50% Pulse 100%AM at 1890 MHz

1 V/m with 1 kHz sine-wave 80%AM from 2000 MHz…2700 MHz

EFT/B immunity

IEC 61000-4-4:

±2 kV at 5 kHz on communications ports

Surge transient immunity

IEC 61000-4-5:

±2 kV line-earth(CM) on communications ports

Conducted RF immunity

IEC 61000-4-6:

10V rms with 1 kHz sine-wave 80%AM from 150 kHz…80 MHz

Enclosure type rating

None (open-style)

Environmental Specifications ControlLogix ControlNet Interface Module
1756-CNB, 1756-CNBR, Series E

Attribute

Value