Specifications

Characteristic

Value

Operational Temperature

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Nb, Operating Thermal Shock):

0 to 60°C (32 to 140°F)

It is accebtable for the ambient slot temperature immediately surrounding this
product to reach 85°C (185°F) maximum

Storage Temperature

IEC 60068-2-1 (Test Ab, Un-packaged Non-operating Cold),

IEC 60068-2-2 (Test Bb, Un-packaged Non-operating Dry Heat),

IEC 60068-2-14 (Test Na, Un-packaged Non-operating Thermal Shock):

-40 to 85°C (-40 to 185°F)

Relative Humidity

IEC 60068-2-30 (Test Db, Un-packaged Non-operating Damp Heat):

5 to 95% non-condensing

Vibration

IEC 60068-2-6 (Test Fc, Operating):

5g @ 10-500Hz

Operating Shock

IEC 60068-2-27 (Test Ea, Unpackaged Shock):

30g

Non-Operating Shock

IEC 60068-2-27 (Test Ea, Unpackaged Shock):

50g

Emissions

CISPR 11:

Group 1, Class A

ESD Immunity

IEC 61000-4-2:

6kV contact discharges

8kV air discharges

Radiated RF Immunity

IEC 61000-4-3:

10V/m with 1kHz sine-wave 80%AM from 30MHz to 1000MHz

10V/m with 200Hz 50% Pulse 100%AM at 900Mhz

EFT/B Immunity

IEC 61000-4-4:

±4kV at 2.5kHz on communications ports

Surge Transient Immunity

IEC 61000-4-5:

±2kV line-earth(CM) on shielded ports

Conducted RF Immunity

IEC 61000-4-6:

10Vrms with 1kHz sine-wave 80%AM from 150kHz to 80MHz

Enclosure Type Rating

None (open-style)

Power Requirements

(1)

1788-CNC

1788-CNCR


5V dc @ 450 mA (maximum)

5V dc @ 475 mA (maximum)

Power Consumption

1788-CNC

1788-CNCR


2.25 watts

2.375 watts

Power Dissipation

1788-CNC

1788-CNCR


2.25 watts or 7.68 BTU/hour

2.375 watts or 8.1 BTU/hour

Wiring Category

(2)

2 - on communications ports