Safe-off connector pinout – Rockwell Automation 2099-BMxxx Kinetix 7000 High Power Servo Drive Installation Instructions User Manual

Page 12

Advertising
background image

12 Kinetix 7000 High Power Servo Drives

Rockwell Automation Publication 2099-IN003B-EN-P - August 2013

Safe-off Connector Pinout

The Kinetix 7000 drive ships with a (9-pin) wiring-plug header with a motion-allowed jumper
installed in the safe-off (SO) connector. With the motion-allowed jumper installed, the safe-off
feature is disabled.

Motion-allowed Jumper

Headers in this table extend the safe-off (SO) connector signals for use in wiring single and
multiple safe-off drive configurations, or to jumper around (not use) the safe-off feature.

Safe-off 9-pin (SO) Connector

Refer to the Kinetix Safe-off Feature Safety Reference Manual, publication

GMC-RM002

, for

more information on wiring safe-off headers.

Safe-off (SO) pin

Also applies to these SO
connector headers

Description Signal

1

Wiring plug header

First-drive wiring header
(cat. no. 2090-XNSM-W)

One side of the normally-closed monitoring
contact of relay 2

FDBK2+

2

Other side of the normally-closed
monitoring contact of relay 2

FDBK2-

3

One side of the normally-closed monitoring
contact of relay 1

FDBK1+

4

Other side of the normally-closed
monitoring contact of relay 1

FDBK1-

5

Coil of safety-relay 2

SAFETY ENABLE2+

6

Return for safety-relay coil power
(both relays)

SAFETY ENABLE-

7

Coil of safety relay 1

SAFETY ENABLE1+

8

Wiring plug header

Motion-allowed jumper

Power for continuous enable of the safety
function, 500 mA max

24V+

9

Power return used for continuous enable of
safety function

24V_COM

IMPORTANT

Pins SO-8 and SO-9 (24V+) are used by only the motion-allowed jumper. When wiring to the
wiring-plug header, the 24V supply must come from an external source.

1 2 3 4 5 6 7 8 9

Motion-allowed Jumper

Wiring Plug Header

Safe-off