Rockwell Automation 2099-BMxxx Kinetix 7000 High Power Servo Drive Installation Instructions User Manual
Page 13

Kinetix 7000 High Power Servo Drives 13
Rockwell Automation Publication 2099-IN003B-EN-P - August 2013
IOD Connector Pinout
IOD pin
Description
Signal
1
Hardware enable 24V DC power supply
HW_Enable_Pwr
2
Hardware enable input
HW_Enable_In
3
Common
HW_Enable_Com
4
Home switch 24V DC power supply
Home_Switch_Pwr
5
Home switch input
Home_Switch_In
6
Common
Home_Switch_Com
7
Positive overtravel 24V DC power supply
Pos_OverTravel_Pwr
8
Positive overtravel limit switch input
Pos_ OverTravel_In
9
Common
Pos_OverTravel_Com
10
Negative overtravel 24V DC power supply
Neg_OverTravel_Pwr
11
Negative overtravel limit switch input
Neg_ OverTravel_In
12
Common
Neg_OverTravel_Com
13
24V registration power
Reg_1_Pwr
14
High speed registration 1 input
Reg_1_In
15
Common for registration
Reg_1_Com
16
24V registration power
Reg_2_Pwr
17
High speed registration 2 input
Reg_2_In
18
Common for registration
Reg_2_Com
19
Reserved
Analog_Input_1
20
Reserved
Analog_Input_1_Ret
21
Reserved
Analog_Input_2
22
Reserved
Analog_Input_2_Ret
23
Analog output 0
Analog_Out_1
24
Analog output common
Analog_Out_1_Ret
25
Analog output 1
Analog_Out_2
26
Analog output common
Analog_Out_2_Ret
IMPORTANT
Signals +24V_PWR and +24V_COM are a 24V DC source you can use for only the inputs listed
above.