Installing the touchscreen driver, Performing a calibration – Rockwell Automation 6176M-xxxx Standard Industrial Monitors Installation Instructions User Manual

Page 18

Advertising
background image

18 Industrial Standard Monitors

Rockwell Automation Publication 6176M-IN001E-EN-P - August 2012

Follow these directions to connect the touchscreen interface.

1. Connect the USB Type A male connector on the included USB cable to the USB Type

A female connector on the monitor.

2. Connect the USB Type B male connector on the USB cable to the USB Type B female

connector on the host computer.

Installing the Touchscreen Driver

Before installing the touchscreen driver, we recommend that you check cable connections and
communication rate for the interface you are using.

You are now ready to install the touchscreen driver found on the Accessories CD or at

http://www.ab.com/linked/industrialcomputers/drivers/monitors.html

.

Performing a Calibration

After installing the driver, follow the calibration instructions in the touchscreen documentation.

Following installation of the touchscreen driver and calibration, the touchscreen is ready to use.

Interface

Action

RS-232

Verify that the supplied RS-232 cable is properly installed between RS-232 input connector on the

monitor and the host’s COM port.

Verify that the communication rate of the COM port matches the touchscreen controller communication

rate.
The controller communication rate is factory-set at 38,400 baud.

USB

Verify that the USB cable is properly installed between the USB input connector on the monitor and a

USB port on the host computer.

Verify that the communication rate of the USB port matches the touchscreen controller communication

rate.
The controller communication rate is factory-set at 38,400 baud.

USB Type B Male
Connector of USB Cable

USB Type A Male
Connector of USB Cable