Mounting clearances panel mounting guidelines – Rockwell Automation 6176M-xxxx Standard Industrial Monitors Installation Instructions User Manual

Page 7

Advertising
background image

Industrial Standard Monitors 7

Rockwell Automation Publication 6176M-IN001E-EN-P - August 2012

Mounting Clearances

Panel Mounting Guidelines

Observe these guidelines when installing the monitor in a panel.

Included with the monitor is Industrial Monitors Cutout Template, publication

6186M-DS001

, with a cutout template for each monitor model.

Cut supporting panels to specifications before installation. Take precautions so metal
cuttings do not enter components already installed in the panel.

Supporting panels must be at least 14 gauge to be sure of proper sealing against water and
dust and to provide proper support. The mounting hardware supplied accommodates
panels up to 6.25 mm (0.25 in.) thick.

IMPORTANT

Do not operate the monitor in an enclosure using minimum clearances unless adequate
ventilation or other cooling methods are used to maintain the monitor temperature at its
specified rating.

ATTENTION: Failure to follow these guidelines may result in personal injury or damage to the
panel components.

Item

Monitor Location

Clearance, min

1

Top

77 mm (3 in.)

2

Side (both)

50 mm (2 in.)

3

Back

50 mm (2 in.)

4

Bottom

50 mm (2 in.)

2

1

3

4

Advertising