Industrial Standard Monitors 3

Rockwell Automation Publication 6176M-IN001E-EN-P - August 2012

Environment and Enclosure Information

Review the information on enclosures and environments before installing the monitor.

European Union Directive Compliance

This monitor meets the European Union Directive requirements when installed within the
European Union or EEA regions and have the CE mark. A copy of the Declaration of Conformity
(DoC) is available at

http://www.rockwellautomation.com/products/certification/ce/index.html

.

ATTENTION: Environment and Enclosure

This equipment is intended for use in a Pollution Degree 2 industrial environment, in overvoltage
Category II applications (as defined in IEC publication 60664-1), at altitudes up to 2000 m (6561 ft)
without derating.

This equipment is considered Group 1, Class A industrial equipment according to IEC/CISPR 11. Without
appropriate precautions, there may be difficulties with electromagnetic compatibility in residential and
other environments due to conducted and radiated disturbances.

UL listed equipment need not be mounted inside another enclosure if NEMA Type and IEC ratings
are not required, but the mounting method must limit the tilt of the monitor to 30° from vertical.
Examples include articulated arm, table-top stand, wall mount or other means having sufficient
mechanical stability and which is secured to the mounting surface. Monitors that are not rack
mounted ship with a gasketed bezel to meet specified NEMA Type, UL, and IEC ratings only when
mounted in an enclosure with equivalent ratings. Subsequent sections of this publication may
contain additional information regarding specific enclosure type ratings that are required to
comply with certain product safety certifications.

In addition to this publication, see the following:

Industrial Automation Wiring and Grounding Guidelines, publication

1770-4.1

, for additional

installation requirements

NEMA Standard 250 and IEC 60529, as applicable, for explanations of the degrees of protection
provided by enclosures

ATTENTION: This monitor is intended to operate in an industrial or control room environment,
which uses some form of power isolation from the public low-voltage mains. Some computer
configurations may not comply with the EN 61000-3-2 Harmonic Emissions standard as specified
by the EMC Directive of the European Union. Obtain permission from the local power authority
before connecting any computer configuration that draws more than 75 W of AC power directly
from the public mains.