Rockwell Automation 2711-PV1000 PanelView 1000 Terminals User Manual

Page 12

Advertising
background image

12 PanelView 1000 Terminals

Publication 2711-IN036J-EN-P - November 2009

To connect the AC power to the PV 1000 terminals:

1. Secure the AC power wires to the L1 and L2N screws on the terminal block.

2. Secure the Earth Ground/Protective Earth wire to the screw on the terminal

block.

3. Apply power to the terminal.

ATTENTION

Improper wiring of the power terminals may result in voltage at the
communication connector shells. Refer to the figure below when wiring.

L1 L2

White
(Neutral)

Green

L1 L2

Black
(Line)

Brown
(Line)

Green (Earth
Ground)

Green/Yellow
(Protective Earth)

Blue
(Neutral)

120/240V AC, 3 Wire,
U.S. Color Code

120/240V AC, 3 Wire,
European Harmonized
Color Code

Power Terminal
Block (fixed)

To Power Source

To Power Source

Advertising