About the Integrated Drive-Motor Power Interface Module

The Kinetix® 6000M Integrated Drive-Motor (IDM) system uses the 2094-SEPM-B24-S IDM
Power Interface Module (IPIM) to connect IDM units to 400V-class Kinetix 6000 or
Kinetix 6200 multi-axis drive systems. The IDM Power Interface Module occupies a single slot
on Kinetix 6000 power rails.

The IDM system is controlled by a real-time sercos II network. The sercos II fiber-optic cables
connect to the IPIM module, which passes real time data to the IDM units by a daisy chained
network cable. A network terminator is required at the last IDM unit.

A hybrid cable provides a means to pass inter-module communication signals and power to each
IDM unit. The network cable and hybrid cable are daisy chained from one IDM unit to another,
with a terminator required at the last IDM unit (see

IPIM and IDM Interconnect

on

page 3

).

Up to 16 IDM units may be daisy chained to an IPIM module (depending on load conditions).
Terminator connectors for the hybrid and network connections are included with each IPIM.

Mount the IPIM module on the power rail in order of decreasing power utilization. See

Determining Mounting Order

on

page 5

for detailed information.

Refer to the Kinetix 6000M Integrated Drive-Motor System User Manual, publication

2094-UM003

, for detailed information on wiring, applying power, troubleshooting, and

integration with ControlLogix®, CompactLogix™, or SoftLogix™ controller platforms.