Kinetix 6000M Integrated Drive-Motor Power Interface Module 5

Publication 2094-IN016A-EN-P - February 2012

Determining Mounting Order

Refer to the

Module Mounting Order Example

diagram below and mount the modules in the

order (left to right) shown. Install modules according to power utilization (highest to lowest)
from left to right starting with the highest power utilization. If power utilization is unknown,
position modules (highest to lowest) from left to right based on the IPIM or AM module
continuous power rating (kW).

Power utilization is the average power (kW) consumed by a servo axis. If the servo axis has been
sized by using Motion Analyzer software, version 6.000 or later, the calculated axis power
required can be used for power utilization. If the servo axis has not been sized in Motion
Analyzer, the following table showing the maximum continuous power for IPIM and AM
modules can be used to determine desired location on a power rail.

Module Type and Continuous Power Output

The IPIM module may be installed on a power rail with an IAM module configured as a
common bus follower, but you will be responsible for configuring the leader for the appropriate
additional capacitance in the follower power rail, including the IPIM module.

Module Mounting Order Example

2094-BM05-S

Axis Module

2094-SEPM-B24-S

IPIM Module

2094-BM03-S

Axis Module

2094-BM02-S

Axis Module

2094-BM01-S

Axis Module

2094-BMP5-S

Axis Module

22.0 kW

15.0 kW

13.5 kW

6.6 kW

3.9 kW

1.8 kW

Highest Power Utilization

Lowest Power Utilization

Integrated Axis

Module

Axis Modules

Shunt

Module

Slot Filler

Module

IPIM Module

Axis Modules