10 Kinetix 6000M Integrated Drive-Motor Power Interface Module

Publication 2094-IN016A-EN-P - February 2012

Wiring the Connectors

You can wire the connectors by using the following guidelines.

Hybrid Cable DC Bus Connector

This connector supplies the DC bus voltage. Three wires from the Hybrid
Power and Communication cable (catalog number 2090-CHBIFS8-12AA

xx)

are used to extend this voltage to the first IDM unit.

Hybrid Cable Communication Signals Connector

The hybrid communication connector extends control power,
communication, and safety signals to the first IDM unit. The
2090-CHBIFS8-12AA

xx cable interfaces with this connector.

Terminal

Description

Signal

Strip Length

mm (in.)

Torque

N•m (lb•in)

1

DC Bus Supply (-)

DC-

DC-

9.7 (0.38)

0.75 (6.6)

2

PE Ground

PE

PE

3

DC bus supply (+)

DC+

DC+

Terminal

Description

Signal

Strip Length

mm (in.)

Torque

N•m (lb•in)

1

Shield

6.4 (0.25)

0.235 (2.0)

2

Control Power +42V DC

42+

42+

3

Control Power -42V DC

42-

42-

4

CAN Bus Shield

IDM CAN SHIELD

SH2

5

IDM CAN Bus Lo

IDM CAN LO

CN-

6

IDM CAN Bus Hi

IDM CAN HI

CN+

7

System OK out to IDMs

IDM SYSOKOUT

OUT

8

System OK return from IDMs

IDM SYSOKRTN

RTN

9

Safety Shield

SAFETY SHIELD

SH3

10

Safety Enable Input 1

SAFETY ENABLE 1+

SE1

11

Safety Enable Common

SAFETY ENABLE-

SE-

12

Safety Enable Input 2

SAFETY ENABLE 2+

SE2

1

DC-

PE

DC+

1

Shield

42+

42-

SH2

CN-

CN+

OUT

RTN

SH3

SE1

SE-

SE2

Advertising