RAC6180 Industrial Computers

13

Publication 6180-IN001B-EN-P

Panel Mounting (with Studs)

ATTENTION: Disconnect all electrical power from the
panel before making cutout.

Make sure the area around the panel cutout is clear.

Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.

Failure to follow these warnings may result in personal
injury or damage to the panel components.

To install the RAC6180 in a panel using 18 mounting studs:
1. Cut an opening in the panel using the panel cutout dimensions

provided on page 10. Carefully drill eighteen 7/32-inch (5.6 mm)
holes for studs as indicated.

2. The 18 mounting studs are factory installed. In the event studs were

removed for clip mounting, you can re–install studs using a 1/8 inch
socket on the end of the stud. Turn stud clockwise to tighten to
approximately 10 inch-pounds (1.1 N•m).

Figure 8
Installing mounting studs

Panel or Enclosure

Mounting Studs

(Qty 18)

Self-Locking Nuts

Spacer

Bezel

Gasket