Panel mounting (with studs) – Rockwell Automation 6180 RAC6180 Industrial Computers Installation Instructions User Manual
Page 13

RAC6180 Industrial Computers
13
Publication 6180-IN001B-EN-P
Panel Mounting (with Studs)
ATTENTION: Disconnect all electrical power from the
panel before making cutout.
Make sure the area around the panel cutout is clear.
Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.
Failure to follow these warnings may result in personal
injury or damage to the panel components.
To install the RAC6180 in a panel using 18 mounting studs:
1. Cut an opening in the panel using the panel cutout dimensions
provided on page 10. Carefully drill eighteen 7/32-inch (5.6 mm)
holes for studs as indicated.
2. The 18 mounting studs are factory installed. In the event studs were
removed for clip mounting, you can re–install studs using a 1/8 inch
socket on the end of the stud. Turn stud clockwise to tighten to
approximately 10 inch-pounds (1.1 N•m).
Figure 8
Installing mounting studs
Panel or Enclosure
Mounting Studs
(Qty 18)
Self-Locking Nuts
Spacer
Bezel
Gasket