Positioning Mode Example (Continued)

4005

!ăalways be the lowest priority task.

4006

!

4010

FOR I% = 0 TO 3 \ READ LIMIT_SWITCH%(I%) \ NEXT I%

4015

RESET@ = TRUE \ RESET@ = FALSE

\!ăZero counter

4020

I% = 0

\!ăInitialize limit switch index

4025

LOW_COMP% = LIMIT_SWITCH%(I%)

\!Set comparator to 1st value

4030

CNTR_EQ_RST@ = FALSE

\!ăInitialize 'Comp=' status

4035

EQU_INT@ = ON

\! Enable comp = interrupt

4040

CLR_MOD1@ = OFF

\! Reset on equal

4045

CLR_MOD2@= ON

\! Reset on equal

4050

CCLK_EN@ = ON

\! Enable constant clock

5988

!

5989

!ăPlace additional initialization software here.

5990

!

5991

!

5992

!ăThe next statement synchronizes the task to the external

5993

!ăevent via the interrupt. Task execution will be suspended

5994

!ăuntil the interrupt occurs. When the interrupt occurs, if

5995

!ăthis task is the highest priority task waiting to

5996

!ăexecute, it will become active. If it is not the highest

5997

!ăpriority task, it will remain suspended until all higher

5998

!ăpriority tasks have executed at which point it will then

5999

!ăbecome active.

6000

!

6010

WAIT ON COUNTER_EVENT

6997

!

6998

!ăThe following statements perform the interrupt service

6999

!ăroutine.

7000

!

7010

INDEX% = I% + 1

\!ăSave this index value

7015

I% = I% + 1 \ IF I% > 3 THEN I% = 0

\!ăStep to next point

7020

LOW_COMP% = LIMIT_SWITCH%( I% )

\!ăSet up next value

7025

CNTR_EQ_RST@ = FALSE

\!ăReset interrupt

7030

ON INDEX% GOSUB 8000, 8200, 8400, 8600 \ !Execute routine

7035

GOTO 6010

7997

!

7998

!ăInterrupt service routine for limit switch value (0).

7999

!

8000

INT_SERVICE0% = INT_SERVICE0% + 1

8190

RETURN

8197

!

8198

!ăInterrupt service routine for limit switch value (1).

8199

!

8200

INT_SERVICE1% = INT_SERVICE1% + 1

8390

RETURN

8397

!

8398

!ăInterrupt service routine for limit switch value (2).

8399

!

8400

INT_SERVICE2% = INT_SERVICE2% + 1

8590

RETURN

8597

!

8598

!ăInterrupt service routine for limit switch value (3).

8599

!

8600

INT_SERVICE3% = INT_SERVICE3% + 1

8790

RETURN

9000

DATA 1000

\!ăLimit switch position 0

9005

DATA 500

\!ăLimit switch position 1

9010

DATA 2500

\!ăLimit switch position 2

9020

DATA 3000

\!ăLimit switch position 3

32767

END