Connecting dc power – Rockwell Automation 6185-C_B Industrial 15 12 Inch Monitor User Manual User Manual

Page 18

Advertising
background image

18

Bulletin 6185-C and 6185-B Industrial Flat Panel Monitors

Publication 6185-5.1

ATTENTION: Chassis ground must be connected for
safe operation of the monitor. The AC receptacle on the
monitor is a 3-wire type with chassis ground pin, and the
mating AC cord supplied is a 3-wire type, designed for
connection to a grounded 3-pin AC outlet. However, a
properly ground AC outlet is not always available, and
grounding using a 3-wire cord can easily be defeated. If
you fail to ground the monitor properly, the setup may
result in personal injury from electrical shock or damage
to the equipment.

3. Connect the socket end of the AC power cord to the mating

connector on the side of the monitor and secure the cord with the
power cord retainer clip. See the figure on page 15.

ATTENTION: EXPLOSION HAZARD! You must
install the power cord retainer clip to ensure safety in
hazardous locations.

Failure to secure the power cord with the retainer clip
could result in hazardous conditions if the power cord is
accidentally disconnected.

ATTENTION: EXPLOSION HAZARD! – Do not
disconnect equipment unless power has been switched off
or the area is known to be non-hazardous.

4. Connect the plug end of the AC power cord to the main outlet.

5. Restore AC power to the outlet.

6. Proceed to Configuring Video Setup on page 20.

Connecting DC Power

The 6185-C and 6185-B monitors with a DC power option require a DC
power supply providing 18 to 32V DC.

To connect DC power to the monitor:

1. Turn off the main switch or breaker.

2. Use the ground terminal on the monitor to establish a chassis-to-

earth ground connection. The ground terminal is an M5 screw.
Secure one end of a ground strap to the ground terminal. Connect the
other end of the ground strap to a good earth ground.

Advertising