Installing a 6185-c monitor into a rack – Rockwell Automation 6185-C_B Industrial 15 12 Inch Monitor User Manual User Manual

Page 40

Advertising
background image

40

Bulletin 6185-C and 6185-B Industrial Flat Panel Monitors

Publication 6185-5.1

Installing a 6185-C Monitor into a Rack

1. Verify that you have eight rack units (14.0”) available to mount your

monitor.

2. Locate holes in the rack mounting rails corresponding to the holes in

the monitor front panel. Install clip nuts behind the holes in the rails
if threaded rails are not provided.

Note:

The mounting rails that run vertically along the inside
edges of the front opening of an EIA rack cabinet can
be of two types:

“Wide” rails have holes spaced 0.5"(12.7 mm) and

1.25"(31.8 mm) on centers, in a repeating pattern.
Wide rails are prevalent in Europe.

“Universal” rails have holes spaced 0.5"(12.7 mm),

0.625"(31.8 mm), and 0.625"(31.8 mm) on centers,
in a repeating pattern. Thus, the universal rails have
a hole pattern that contains the wide pattern but
provides an additional hole at the midpoint of the
pattern. Universal rails are most prevalent in the US.

3. Install the monitor into the cabinet from the front.

4. Secure the monitor chassis to the cabinet by installing panel-

mounting screws through the holes in the monitor’s front panel and
into the rails behind.