Panel Mounting

To install the RAC6182 Computer in a panel:

ATTENTION: Disconnect all electrical power from the panel
before making cutout.

Make sure the area around the panel cutout is clear.

Take precautions so that metal cuttings do not enter any
components that are already installed in the panel.

Failure to follow these warnings may result in personal injury
or damage to the panel components.

1. Cut an opening in the panel using the panel cutout dimensions provided on

Page 9.

2. Make sure the RAC6182 Computer sealing gasket is properly positioned on

the terminal. This gasket forms a compression type seal. Do not use sealing
compounds.

3. Place the RAC6182 Computer in the panel cutout.

4. Install the mounting clips. The mounting clips slide into the slots on the top

and bottom of the RAC6182 Computer.