RAC6182 Industrial Computer 11

Publication 6182-IN001D-MU-P

5. Gradually tighten the clips one at a time around the bezel using the specified

sequence. Repeat this process at least three times until the clips are hand tight
and the gasket is compressed uniformly against the panel.

6. Tighten mounting clips to a torque of 10 inch–pounds (1.1 N•m) in the

sequence shown above. Do not over–tighten.

ATTENTION: Tighten mounting clips to a torque of 10 inch–
pounds (1.1 N•m) to provide a proper seal and prevent damage
to the RAC6182 Computer. Rockwell Automation assumes no
responsibility for water or chemical damage to the terminal or
other equipment within the enclosure because of improper
installation.