Rockwell Automation 9220-CC QUICK START CONTROLNET NTWK User Manual

Page 13

Advertising
background image

ControlNet Network Compliance Tool

13

Publication 9220-10.3 — September 1997

Special Logging Options

Optional parameters specify additional logging options. If no logging
options are specified, the default operation logs and displays all
information without the debug information.

c:\tool_directory>dev_tst.exe 75 1 8

MAC ID of the

MAC ID of the test platform

MAC ID of the DUT

Test number

1

1

1

Log option

Debug optio

n

User comment

If

Use this log option

only the failed test information needs to be displayed and
logged

1

only the failed test information and test number of passed test
need to be displayed and logged

2

both passed and failed information needs to be displayed and
logged

3

If

Use this debug option

the debug information needs to be displayed

1

the debug information needs to be displayed and logged

2

If a user comment is needed in the log file, set the user comment
parameter to a non-zero value.

"

Advertising