Rockwell Automation 9220-CC QUICK START CONTROLNET NTWK User Manual
Page 13
ControlNet Network Compliance Tool
13
Publication 9220-10.3 — September 1997
Special Logging Options
Optional parameters specify additional logging options. If no logging
options are specified, the default operation logs and displays all
information without the debug information.
c:\tool_directory>dev_tst.exe 75 1 8
MAC ID of the
MAC ID of the test platform
MAC ID of the DUT
Test number
1
1
1
Log option
Debug optio
n
User comment
If
Use this log option
only the failed test information needs to be displayed and
logged
1
only the failed test information and test number of passed test
need to be displayed and logged
2
both passed and failed information needs to be displayed and
logged
3
If
Use this debug option
the debug information needs to be displayed
1
the debug information needs to be displayed and logged
2
If a user comment is needed in the log file, set the user comment
parameter to a non-zero value.
"