background image

Chapter 3

Installation

3–2

Figure 3.1 Inserting the MATH-PAK installation card

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

ЗЗЗЗ

MATH-PAK
installation
card

Color CVIM
module

Archive
Memory slot

Card Label

Metal Strip

The loading process requires about 45 seconds. The LEDs near the top of
the face of the Color CVIM module indicate the progress of the
three–phase loading process (with each phase taking about 15 seconds):

LEDs

MATH-PAK Loading Phase

LEDs

1

2

3

Pass/Fail

Red–to–yellow–

to–green

Green

Red–to–yellow–

to–green

Trigger 1

Green

Green

Off

Trigger 2

Off

Green

Green

When the loading process is complete, the Color CVIM module initiates
its normal powerup sequence.

Once the powerup sequence is complete, you can verify that the
MATH-PAK option is installed by checking for the MATH-PAK
indication on the powerup title banner on the monitor; if the MATH-PAK
option is installed, it is listed as on of the “Packages” on the title banner,
along with other installed options, if any.

Remove the MATH-PAK installation card from the Archive Memory slot.

At this point, the MATH-PAK option has been successfully installed, and can
be used as required in your Color CVIM module configurations.