Enabling / disabling a formula – Rockwell Automation 5370-CMPK Color CVIM Module MATH-PAK User Manual

Page 53

Advertising
background image

Chapter 4

Defining Formulas

4–38

Enter the desired formula name, by picking the appropriate keys on the
keyboard (see Chapter 5 in the Color CVIM User’s Manual for more
keyboard usage information). Pick

Ret

when the name is entered as

desired. When you do, this message appears:

Name restrictions: Names can contain up to seven characters, including
spaces. Any additional characters entered are truncated from the right.

Once you have defined a formula’s contents, you must then enable the
formula, in order for the formula to function as part of the configuration, and
in order to set range limits and assign outputs for the formula.

Define formula first: The

Formula #: Disabled

box for a selected formula

is itself disabled until the formula has been defined. Thus you cannot enable
a formula until you first define it (see “Defining a Formula” in this chapter).

To enable a formula:

Pick the

Formula #: Disabled

box on the

Config. Results

menu (see

Figure 4.20).

Figure 4.20 Enabling a formula

Formula #: Disabled box

A warning message appears, listing the corresponding gage or window
which is affected.

Enabling / Disabling a
Formula

Advertising