Runtime tools displays – Rockwell Automation 5370-CMPK Color CVIM Module MATH-PAK User Manual
Page 67

Chapter 5
Analysis Functions and Runtime Displays
5–4
Runtime Tools Displays
With MATH-PAK installed, the tools displays,
All Tools
and
Failed Tools
,
will include the enabled formulas. Formulas are displayed by formula name,
in numerical order, in the top left corner of the screen (see Figure 5.5).
Figure 5.5 Formulas displayed in Failed Tools display during run mode operation
Formulas
listed in red (or
yellow)
Tools displayed
in red (or
yellow)
During runtime, any enabled formulas are listed according to the runtime
Display
menu selection (see Figure 5.5):
All Tools
– Displays all enabled tools and formulas. The displays are
color-coded – failed tools and formulas are displayed in red; tools which
are within fault range limits, but not within warning range are displayed
in yellow; tools which are within all range limits are green.
Failed tools –
Displays only the tools and formulas whose results are
beyond the fault (red) and/or warning range (yellow).
I/O Page
Formula output status is displayed on the
I/O Page
during run mode –
formula results are found on the third page of the
I/O Page
display.
As with other tool output status, formula output status is color-coded – green
(pass), yellow (warning), or red (fault).