Chapter 5

Analysis Functions and Runtime Displays

5–4

Runtime Tools Displays

With MATH-PAK installed, the tools displays,

All Tools

and

Failed Tools

,

will include the enabled formulas. Formulas are displayed by formula name,
in numerical order, in the top left corner of the screen (see Figure 5.5).

Figure 5.5 Formulas displayed in Failed Tools display during run mode operation

Formulas
listed in red (or
yellow)

Tools displayed
in red (or
yellow)

During runtime, any enabled formulas are listed according to the runtime

Display

menu selection (see Figure 5.5):

All Tools

– Displays all enabled tools and formulas. The displays are

color-coded – failed tools and formulas are displayed in red; tools which
are within fault range limits, but not within warning range are displayed
in yellow; tools which are within all range limits are green.

Failed tools –

Displays only the tools and formulas whose results are

beyond the fault (red) and/or warning range (yellow).

I/O Page

Formula output status is displayed on the

I/O Page

during run mode –

formula results are found on the third page of the

I/O Page

display.

As with other tool output status, formula output status is color-coded – green
(pass), yellow (warning), or red (fault).