Chapter 4

Defining Formulas

4–45

Using the learn mode statistics: You can run a series of trial inspections,
using a representative sample of workpieces, with the Color CVIM module
in Learn mode, in order to accumulate a statistical basis for setting the

FAULT

RANGE

and

WARNING RANGE

limits. For more information on

the learn mode, refer to the Chapter 20 in the Color CVIM User’s Manual.

Example Range Limit Setting

Here is an example of setting the range limit values for a formula:

AVG(GAGE1, GAGE2, GAGE3)

which averages the values of three gages (see Figure 4.23), in relation to the
REFERENCE value:

The REFERENCE (ideal or nominal) value is 15.000.

WARNING

RANGE

Low

14.800.

High

15.200.

FAULT

RANGE

Low

14.600.

High

15.400.

With the range limits set as shown above, if a formula result is outside either

WARNING

RANGE

limit (above 15.200 or below 14.800), but within the

FAULT RANGE

limits, the formula will have a

WARNING

condition only.

If an inspection result is outside either

FAULT

RANGE

limit (above 15.400

or below 14.6), the formula will have both a

WARNING

and a

FAULT

condition.

Figure 4.23 Example: Range limits for linear gaging

A

B

15 cm (Ideal)

Gages measure distance
from feature A to feature B

A

B

A

B

Gage 1

Gage 2

Gage 3

Here is an example of setting the range limit values for a conditional
operation by a formula (see Figure 4.24, page 4–46), where the
REFERENCE value, 1, is the only acceptable value: