Statistics (learn mode) for failed tools – Rockwell Automation 5370-CMPK Color CVIM Module MATH-PAK User Manual

Page 65

Advertising
background image

Chapter 5

Analysis Functions and Runtime Displays

5–2

With MATH-PAK installed, the Color CVIM module allows you to select
whether you will include or exclude data from failed tools when collecting
statistics (when running the Color CVIM in learn mode).

You determine whether data from failed tools is included in the statistics
through the use of the

Range Fail

box on the

Runtime Init.

menu (see

Figure 5.2):

Pick

Exit

Runtime Init.

to access the

Runtime Init.

menu.

Pick the

Range Fail:

box to toggle the setting between

No Stats

and

Stats.

The effects of the

Range Fail

selection are as follows:

Stats

: Statistics collected will include results from failed tools as well as

from tools which pass.

No Stats

: Statistics collected will include results only from tools which

pass.

Figure 5.2 The Range Fail box

Range Fail box

Statistics (Learn Mode) for
Failed Tools

Advertising