Entering range limits for formulas – Rockwell Automation 5370-CMPK Color CVIM Module MATH-PAK User Manual
Page 58
![background image](/manuals/580817/58/background.png)
Chapter 4
Defining Formulas
4–43
output line, and assign both the
High
and
Low
FAULT RANGE
limits to
another
Results
output line.
Formulas prevent the use of associated gage and window outputs: Any
formula you select and enable will disable the use of results outputs from a
corresponding gage or window (as listed in Table 4.A, page 4–3).
Entering Range Limits for Formulas
After you determine the appropriate
FAULT RANGE
and/or
WARNING
RANGE
limit values for a formula, you can enter these values using the
range/output setup table.
Define and enable formula first: A formula must be both defined and
enabled before you can enter range limits.
To access the range/output setup table for a formula:
•
Pick
Range/Outputs
on the
Config. Results
menu to display the
range/output table (see Figure 4.22).
Figure 4.22 Assigning range limits
Calculator pad
Inspection
statistics
table
Range/output
table
If all range limits are currently set to zero as shown in Figure 4.22, enter the
appropriate
High
and
Low
FAULT RANGE
and/or
WARNING RANGE
limits in the following order:
1.
Pick the
High
box under
FAULT RANGE
. When you do, the calculator
pad appears, as shown in Figure 4.22.