Follow these steps to mount an axis module on the Kinetix 2000 power rail.

1. Align the module locking screw with its corresponding slot on the power rail.
2. Push the module straight forward, by applying force at the top and bottom edges of the

front cover.

The module is fully seated when each locking clip snaps into the bottom of the power
rail and the locking screw boss is flush at the top of the power rail.

3. Torque mounting screw to 0.7 N•m (6.0 lb•in).

IMPORTANT

The IAM module must be positioned in the leftmost slot of the power rail, followed by AM
modules in descending order of power utilization.

ATTENTION: To avoid damage to pins on the back of each module, and to make sure that module
pins mate properly with the power rail, install modules as shown below.

ATTENTION: The power rail must be mounted with the connectors in an upright or vertical
orientation to the panel. This provides proper cooling of the modules. Do not mount modules if the
power rail is not within 3° of vertical.