Contactor enable and power connector pinouts – Rockwell Automation 2093-AMxx Kinetix 2000 Integrated Axis Module and Axis Module Installation Instructions User Manual

Page 8

Advertising
background image

8 Kinetix 2000 Multi-axis Servo Drives

Rockwell Automation Publication 2093-IN001B-EN-P - July 2013

Connector Descriptions

Contactor Enable and Power Connector Pinouts

These connectors are supplied with removable wiring plugs. The pins are numbered
consecutively from top to bottom.

Contactor Enable (CED) Connector

Control Power (CPD) Connector

Designator Description

Connector

BC

Motor brake

4-position plug/header

CED

(1)

(1)

Connector is only on integrated axis modules (catalog numbers 2093-AC05-MP

x).

Contactor enable

2-position plug/header

CPD

(1)

Control input power (drive)

2-position plug/header

DPI

(1)

Drive peripheral interface (factory use only)

8-pin mini-DIN

IOD/AF

User I/O (drive) and auxiliary feedback

44-pin high-density D-shell (female)

IPD

(1)

230V AC input power (drive) and DC bus

6-position plug/header

MF

Motor feedback

15-pin high-density D-shell (female)

MP

Motor power

4-position plug/header

Tx and Rx

SERCOS transmit and receive

SERCOS fiber-optic (2)

IMPORTANT

These connectors are available only on integrated axis modules (catalog numbers
2093-AC05-MP

x).

CED Pin

Description

Signal

1

Relay-driven dry contact used in the safety string for a three-phase power
contactor.

CONT EN+

2

CONT EN-

CPD Pin

Description

Signal

1

Control power VAC input line 1

CTRL 1

2

Control power VAC input line 2

CTRL 2

Advertising