U.008 – Rockwell Automation Liqui-Flo AC GP Vector Drive Version 6.4 User Manual
Page 62

2-28
LiquiFlo AC Drive, Software Reference Version 6.4
What Happens if a Fault Occurs During Self-Tuning?
1.
If the drive stops due to a fault, the motor will coast to stop. A self-tuning fault code
(SF) will be displayed and must be cleared. Refer to chapter 5 for more
information.
2.
Once the drive is stopped, parameter U.008 will be reset to OFF and the
self-tuning procedure will be completed. The results are stored in U.009, Torque
Self-Tune Result.
Step 8.1 Press the ▼
key to display U.008, Torque Self-Tune Enable.
Parameter U.008 is displayed.
Step 8.2 Press the ENTER key.
The default setting of OFF is displayed.
Step 8.3 Press the ▲
key to enable the self-tuning procedure.
On is displayed.