Replace only the actuator cylinder, Assemble the electric cylinder – Rockwell Automation TLAR Electric Cylinders Replacement  User Manual

Page 10

Advertising
background image

10 MP-Series and TL-Series Electric Cylinders Replacement Parts

Rockwell Automation Publication MPAR-IN002B-EN-P - September 2012

Replace Only the Actuator Cylinder

1.

Remove the coupling hub from the actuator cylinder.

2.

Remove the bolt from the coupling hub.

3.

Position the coupling hub on the shaft of the actuator cylinder.

Use the dimension shown on the table in

step 6

on page

9

.

4.

Tighten the coupling hub bolt to the torque shown on the table in

step 6

on page

9

.

Continue with

Assemble the Electric Cylinder

on

page 10

.

Assemble the Electric Cylinder

1.

Attach the coupling housing by using four bolts.

2.

Torque the bolts as shown in this table.

3.

Attach the motor flange by using the required number of bolts.

See table in following the step for the bolt quantity.

Cat. No.

Bolt
Size

Torque
N•m (lb•in)

Cat. No.

Bolt
Size

Torque
N•m (lb•in)

MPAR-x1xxxx-xxA

M6 x 30

4.2 (37.17)

TLAR-A1xxxB-BxA

M6 x 20

4.2 (37.17)

MPAR-x2xxxC-xxA

TLAR-A1xxxE-BxA

MPAR-x2xxxF-xxA

TLAR-A2xxxC-BxA

MPAR-x3xxxE-xxA

M8 x 40

7.8 (69)

TLAR-A2xxxF-BxA

MPAR-x3xxxH-xxA

TLAR-A3xxxE-BxA

M8 x 40

7.8 (69)

TLAR-A3xxxH-BxA

Coupling Housing

Actuator Cylinder

Coupling Housing

Actuator Cylinder

Motor Flange

Advertising