Before You Begin

Before you begin, use the

Catalog Number Explanation

to verify that the replacement parts

match the electric cylinder that you are attempting to repair. Read through the procedure before
beginning repair or replacement.

Replace Inline-mount Electric Cylinder Motor

This procedure applies to Bulletin MPAR-

xxxxxx-xxA and TLAR-xxxxxx-xxA electric

cylinders.

Follow these steps to replace the motor.

1.

Disconnect motor and feedback cables.

2.

Remove the four bolts that secure the motor to the motor flange.

3.

Remove the bolt from the coupling hub on the motor shaft.

4.

Remove the coupling hub from the motor shaft.

5.

Clean the replacement motor shaft with a soft cloth damped with isopropyl alcohol.

6.

Position the coupling hub on the replacement motor’s shaft.

Use the dimension from the table on page

7

.

7.

Torque the coupling bolt to the value listed in the table on page

7

.

IMPORTANT

Apply Loctite 222 to bolts

 M4 and Loctite 242 for bolts  M5 during assembly steps.