Rockwell Automation TLAR Electric Cylinders Replacement  User Manual

Page 12

Advertising
background image

12 MP-Series and TL-Series Electric Cylinders Replacement Parts

Rockwell Automation Publication MPAR-IN002B-EN-P - September 2012

Replace a Parallel-mount Electric Cylinder Motor or Belt

This procedure is for Bulletin MPAR-

xxxxxx-xxB/D/E electric cylinders. These steps can be

used to change the motor or the actuator cylinder orientation.

Follow these steps to replace the belt, motor, or actuator cylinder.

1.

Disconnect the motor and feedback cables.

2.

If the motor has brake, release the brake on motor so that the rod moves freely.

3.

Position the rod to the center of travel.

4.

Remove the cover from belt housing.

IMPORTANT

Apply Loctite 222 to bolts

 M4 and Loctite 242 for bolts M5 during assembly steps.

ATTENTION: Exposed moving parts can cause severe injury. Do not the operate electric cylinder
without the cover in place. Follow the lock-out procedures before servicing the machine.

CAUTION

Hot sur

face.

Do not t

ouch.

Belt Housing

Advertising