14 MP-Series and TL-Series Electric Cylinders Replacement Parts

Rockwell Automation Publication MPAR-IN002B-EN-P - September 2012

a. Remove the bolts from the motor or actuator cylinder.

Be sure to collect all the square nuts if you are removing the motor.

b. Reposition the motor and or actuator cylinder.

c. Attach the actuator cylinder with four bolts.

d. Torque the actuator cylinder bolts to values shown in this table.

e. Attach the motor by using four bolts and four square nuts.

Do not tighten bolts at this time.

8.

Place the spacer rings, belt, and pulleys on the shafts.

Bottom out pulleys to make them parallel.

IMPORTANT

If you are mounting the motor with the connectors between the actuator cylinder
and the motor, rotate the motor connectors so they exit 180° away from the shaft.

Cat. No.

Bolt
Size

Torque
N•m (lb•in)

MPAR-x1xxxB-xxB/D/E

M6 x 18

4.2 (37.17

MPAR-x1xxxE-xxB/D/E

MPAR-x2xxxC-xxB/D/E

MPAR-x2xxxF-xxB/D/E

MPAR-x3xxxE-xxB/D/E

M8 x 20

7.8 (69)

MPAR-x3xxxH-xxB/D/E