Rockwell Automation TLAR Electric Cylinders Replacement User Manual
Page 9
MP-Series and TL-Series Electric Cylinders Replacement Parts 9
Rockwell Automation Publication MPAR-IN002B-EN-P - September 2012
6.
Tighten the clamping bolts on both the coupling hubs to the specified torque.
Continue with
Assemble the Electric Cylinder
Cat. No.
X
1
(1)
mm (in.)
(1)
Tolerance is ± 0.25 mm (0.010 in.).
Y
1
(1)
mm (in.)
Torque
N•m (lb•in)
Cat. No.
X
1
(1)
mm (in.)
Y
1
(1)
mm (in.)
Torque
N•m (lb•in)
MPAR-x1xxxB
18.5
(0.73)
19.3
(0.76)
4.0 (35.4)
TLAR-x1xxxB
25.0
(0.98)
16.8
(0.66)
0.6 (5.31)
MPAR-x1xxxE
TLAR-x1xxxE
28.8
(1.13)
19.3
(0.76)
4.0 (35.4)
MPAR-x2xxxC
19.5
(0.77)
18.3
(0.72)
TLAR-x2xxxC
29.8
(1.17)
18.3
(0.72)
MPAR-x2xxxF
22.3
(0.88)
TLAR-x2xxxF
MPAR-x3xxxE
35.5 (1.4)
27.0
(1.06)
8.0 (70.8)
TLAR-x3xxxE
30.5
(1.20)
27.0
(1.06)
8.0 (70.8)
MPAR-x3xxxH
35.2
(1.38)
TLAR-x3xxxH
Use the dimension from the table.
Motor
X
1
Y
1
Actuator Cylinder