IntelliCENTER Software 39

Publication MCC-UM001E-EN-P - March 2014

3. Select an MCC lineup and one of its Ethernet networks to begin the mapping.

You must choose one of the device naming conventions:

• NameplateText_NetworkNumber_IPAddress - the unit nameplates are used to determine the device names in I/O tree
• DeviceType_NetworkNumber_IPAddress - the device type is used instead

4. Click Next.

You are prompted to add devices to the controller I/O tree in your project:

• The Ethernet Cards pull-down menu contains all the Ethernet cards in your project.
• The Available Devices dialog box lists the devices for the lineup/network which can be mapped.