Monitored Availability can be used as a real-time override of Scheduled Availability. It is
commonly used to prevent Available Time from accumulating if the workcell is scheduled
to be available but cannot produce due to some factor that is beyond its control.
C
USTOM
E
VENTS
- M
ONITORED
V
ALUE
The UDT contains one tag that is configured in FactoryTalk Metrics as a Monitored Value
custom event. It is assumed that this tag will always contain a meaningful value, such as
machine state code.
Line
UDT Field Name
Data Type
FactoryTalk Metrics
use
Scheduled/Unscheduled
8
Monitored_Availability
BOOL
Monitored Availability Unscheduled
Line
UDT Field Name
Data Type
FactoryTalk Metrics
use
Scheduled/Unscheduled
9
Monitored_Value
Integer
Custom Event
(Monitored Value
type)
Unscheduled
Using the Configuration Console, you can create a list to convert the numeric values returned by
this data point into string values for easier reporting. See the FactoryTalk Metrics User’s Guide.