3. Click Load from database to load the list of workcells configured in the plant model

into the SQL Server database. The same data that appears on this tab will also appear
on the FactoryTalk Transaction Manager and FactoryTalk Metrics tabs.

C

REATING

AND

IMPORTING

THE

F

ACTORY

T

ALK

T

RANSACTION

M

ANAGER

CONFIGURATION

The configuration tool’s FT Transaction Manager tab allows you to:

„

Create the FactoryTalk Transaction Manager configuration if it does not exist.

„

Select the workcells in the plant model to be configured with performance parameters.

„

For each workcell to be configured, identify the location in the control system where
the UDT is located.

„

Create the transactions necessary to configure the performance parameters for the
selected workcells by creating an XML data file and then importing that file into
FactoryTalk Transaction Manager.

1. Click the FT Transaction Manager tab:

If you intend to use an existing FactoryTalk Transaction Manager configuration, that
configuration must contain a FactoryTalk Live Data control connector and a FactoryTalk
Metrics enterprise connector.

On this tab you will
select the location
where you want to
store the XML output
file and then enter the
information for the
configuration file you
are about to create
(including the
application you
created earlier).

Designate each
UDT’s area, shortcut,
structure name, and
position in the array
before generating the
XML file and
importing it into
FactoryTalk
Transaction Manager.