Introduction

1-3

1.1

Field Power Module

The single-phase Field Power Module is integrally mounted within the SD3100 Power
Module to provide the motor field excitation. The Field Power Module is rated 15 or 60
amps at 230/460 VAC. The 15A unit is supplied as standard. The 60A unit is available
as an option.

The Field Power Module requires a separately-ordered, separately-mounted field
isolation transformer. The Field Power Module’s AC input lines are connected through
the isolation transformer to the L1 and L3 inputs of the SD3100. The 15A module
requires a step-down transformer rated up to 7.5kVA (application dependent). The
60A module requires a step-down transformer rated 7.5kVA to 25kVA (application
dependent). All systems operate on three-phase 50/60 Hz., 460 to 660 VAC.

The Field Power Module is available in the configurations listed in table 1.2.

1.2

Standard Features

SD3100 DC Power Modules have the following features:

Three-phase 460, 575, or 690 VAC input

1250, 1650, and 3000 amp units

S6 (non-regenerating) and S6R (regenerating) configurations

15 amp Field Power Module

DC output contactor

PE / TE bus

Choice of incoming circuit breaker or input line fuse protection

Electronic motor overload protection

SCR power semiconductors / dv/dt protection

SCR leg fuses

Cell chokes

Protection against unequal current sharing among SCRs

Protection from AC line dips and transients

Top AC entry / Bottom DC exit

Power through-bus (1250A and 1650A Power Modules)

Table 1.2 – Field Power Module Part Numbers

Part No.

Amps

AC Input

Description

Mounting

805405-3R

1

1. For application information see instruction manual S-3060.

15

230 / 460 VAC

Reversing (S2R)

Integral

805405-5R

1

60

230 / 460 VAC

Reversing (S2R)

Integral