Ultra3000 Drive Systems

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.

Ultra3000 (400V class) Drives/MP-Series Low Inertia Motor Curves

MPL-B880D

2000

47.0

77.4 (685)

94.0

144 (1275)

12.6

2098-DSD-HV220

MPL-B960B

1200

42.5

130 (1150)

94.0

231 (2050)

12.7

2098-DSD-HV220

MPL-B960C

1500

41.5

112 (990)

94.0

181 (1600)

14.8

2098-DSD-HV220

MPL-B980B

1000

40.0

163 (1440)

94.0

278 (2460)

15.2

2098-DSD-HV220

MPL-B980C

1500

47.5

118.6 (1050)

94.0

213 (1890)

16.8

2098-DSD-HV220

Bulletin MPL Motor Performance Specifications with Ultra3000 (400V class) Drives (continued)

Rotary Motor

Speed, max
rpm

System Continuous
Stall Current
A (0-pk)

System Continuous
Stall Torque
N•m (lb•in)

System Peak
Stall Current
A (0-pk)

System Peak
Stall Torque
N•m (lb•in)

Motor Rated
Output
kW

Ultra3000
400V-class Drives

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2000

4000

6000

8000

0

2098-DSD-HV030 and MPL-B1510V

0.800

0.700

0.600

0.500

0.400

0.300

0.200

0.100

0

7.08

6.19

5.31

4.42

3.54

2.65

1.77

0.88

0

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2000

4000

6000

8000

0

2098-DSD-HV030 and MPL-B1520U

1.600

1.400

1.200

1.000

0.800

0.600

0.400

0.200

0

14.1

12.4

10.6

8.85

7.08

5.31

3.54

1.77

0

Intermittent curve represents

460V and 400V inputs

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2000

4000

6000

8000

0

2098-DSD-HV030 and MPL-B210V

1.600

1.400

1.200

1.000

0.800

0.600

0.400

0.200

0

14.1

12.4

10.6

8.85

7.08

5.31

3.54

1.77

0

Torque

(N•m)

Torque
(lb•in)

Speed (rpm)

2000

4000

6000

8000

0

2098-DSD-HV030 and MPL-B1530U

4.00

3.50

3.00

2.50

2.00

1.50

1.00

0.50

0

35.4

30.9

26.5

22.1

17.7

13.3

8.84

4.42

0

= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage