Bulletin MPS Motor Performance Specifications with Ultra3000 (400V class) Drives

Performance specification data and curves reflect nominal system performance of a typical system with motor at 40 °C (104 °F) and drive at 50 °C (122 °F) ambient and rated line voltage. For additional
information on ambient and line conditions, refer to Motion Analyzer software, version 4.7 or later.

Ultra3000 (400V class) Drives/MP-Series Stainless Steel Motor Curves

Rotary Motor

Speed, max
rpm

System Continuous
Stall Current
A 0-pk

System Continuous
Stall Torque
N•m (lb•in)

System Peak Stall
Current
A 0-pk

System Peak Stall
Torque
N•m (lb•in)

Motor Rated
Output
kW

Ultra3000
400V-class Drives

MPS-B330P

5000

4.90

3.6 (32)

14.0

8.80 (78)

1.3

2098-DSD-HV030

19.0

11.10 (98)

2098-DSD-HV050

MPS-B4540F

3000

7.0

8.0 (71)

14.0

15.6 (138)

1.4

2098-DSD-HV030

7.1

8.1 (72)

22.0

23.5 (208)

2098-DSD-HV050

26.0

27.1 (240)

2098-DSD-HV100

MPS-B560F

3000

17.0

21.5 (190)

46.0

50.1 (443)

3.5

2098-DSD-HV100

68.0

67.7 (599)

2098-DSD-HV150

Torque

(N•m)

Torque
(lb•in)

2098-DSD-HV050 and MPS-B330P

Speed (rpm)

0

2000

4000

3000

1000

5000

12.0

10.0

8.0

6.0

4.0

2.0

0

106

88.5

70.8

53.1

35.4

17.7

0

Torque

(N•m)

Torque
(lb•in)

2098-DSD-HV100 and MPS-B4540F

30

25

20

15

10

5

0

265

221

177

133

88.5

44.2

0

Speed (rpm)

0

3000

2000

1000

500

1500

2500

Torque

(N•m)

Torque
(lb•in)

2098-DSD-HV150 and MPS-B560F

70

60

50

40

30

20

10

0

619

531

442

354

265

177

88.5

0

Speed (rpm)

500

1000 1500 2000

0

2500 3000

= Intermittent operating region
= Continuous operating region
= Drive operation with 400V AC (rms) input voltage