Rockwell Automation 2098-DSD-xxx Ultra3000 Drive Systems Design Guide User Manual

Page 68

Advertising
background image

68

Rockwell Automation Publication GMC-RM008A-EN-P - September 2011

Ultra3000 Drive Systems

Ultra3000 (400V class) Drives/LDC-Series Linear Motor Curves

200

160

120

80

40

0

45.0

36.0

27.0

18.0

9.0

0

2098-DSD-HV030 and LDC-C030100-DHT

Force

(N)

Force
(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling

No Cooling

Intermittent curve represents

460V and 400V inputs

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2098-DSD-HV100 and LDC-C030200-DHT

Force

(N)

Force
(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling

No Cooling

Intermittent curve represents

460V and 400V inputs

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2098-DSD-HV030 and LDC-C030200-EHT

Force

(N)

Force
(lb)

Velocity (m/s)

2

8

6

0

12

10

4

Water Cooling

Air Cooling

No Cooling

400

320

240

160

80

0

89.9

71.9

53.9

36.0

18.0

0

2098-DSD-HV030 and LDC-C050100-DHT

Force

(N)

Force
(lb)

Water Cooling

Air Cooling

No Cooling

Velocity (m/s)

2

8

6

0

12

10

4

800

640

480

320

160

0

180

144

108

72.0

36.0

0

2098-DSD-HV100 and LDC-C050200-DHT

Force

(N)

Force
(lb)

Water Cooling

Air Cooling

No Cooling

Velocity (m/s)

2

8

6

0

12

10

4

800

640

480

320

160

0

180

144

108

72.0

36.0

0

2098-DSD-HV030 and LDC-C050200-EHT

Force

(N)

Force
(lb)

Velocity (m/s)

6

4

0

8

2

Water Cooling

Air Cooling

No Cooling

= Intermittent operating region
= Intermittent operating region with 400V AC (rms) input voltage
= Continuous operating region