6.6. Operation with one thyristor driver removed

The Pulse Generator and Monitoring Module interfaces to two Thyristor drivers from each channel.
The design is such that each channel can operate with one thyristor driver removed. Loss of feedback
from both thyristor drivers of one rod does not affect control of any other rods.

6.7. Detection of a missing pulse

Detection of a missing pulse is primarily intended to detect a failed thyristor in an otherwise working
driver this is found by detecting a dip in the DC waveform.

6.8. Detection of an extra pulse

If an extra pulse is generated this will be caused by a faulty firing of a thyristor.

Shorted Gate Pattern

Normal Waveform

Missing Pulse

Missing Phase

Normal Waveform