Rockwell Automation HPK-Series Asynchronous Servo Motor User Manual

Page 12

Advertising
background image

12 HPK-Series Asynchronous Servo Motors

Publication HPK-IN001C-EN-P - June 2010

6.

Route power cables into the junction box.

The table lists the access hole diameters for the junction box, and the maximum width of
the wire terminal inside the junction box.

The diagram below depicts the threaded access ports on the HPK-

x13xx and

HPK-

x16xx motors, and the connector block or terminal strip connections.

HPK-x13xx and HPK-x16xx Power Cable Access and Wiring

IMPORTANT

The recommended wire size is based on motor current requirements and
terminal block sizing. Consult your local electrical code before selecting wire
gauge for your application.

Motor Catalog No.

Dia. A, Max.

mm (in.)

Dia. B, Max.

mm (in.)

Wire Terminal
Max Width

mm (in.)

HPK-x1307, HPK-x1308, HPK-x1310

35 (1.4)

21 (0.84)

19 (0.75)

HPK-x1609, HPK-x1611, HPK-x1613

45 (1.8)

20 (0.825)

HPK-x1815, HPK-x2010, HPK-x2212,
HPK-B2510

(1)

(1)

Wire selection and access port sizing are determined and performed by the end user as they are application dependent.

Blank access plate

63.5 (2.5) spacing of
copper bus bars

ATTENTION: Unshielded power connections should not extend beyond the
terminal block body.

Failure to observe these safety procedures could result in damage to the motor,
cables, and connector components.

Dia. A

Dia. B

Ground and Shield
Connect to Lug

Max. Width
of Wire
Terminal

LINE 1

LINE 2

LINE 3

U

V

W To

HPK

Motor

Terminal Blocks

From Input Power

External View of
Junction Box Showing
Access Port Locations

Internal View of
Junction Box Showing
Terminal Block Wiring