HPK-Series Asynchronous Servo Motors 31

Publication HPK-IN001C-EN-P - June 2010

Lubrication Amounts and Intervals

The tables below list the recommended amount and interval for lubrication of HPK-Series
motors.

Chevron SRI-2 or equivalent grease is recommended, unless the motor nameplate specifies a
special grease.

Catalog Number

Volume

Weight

HPK-B or HPK-E

Cubic
Centimeter

Cubic Inches

Grams

Ounces

1307…1815 Lubricated

for

life

2010, 2212 or 2510

32

2.0

28

1.0

Service Condition

Ambient
Temperature

(2)

(2)

Specially designed motors are required for operation in ambient temperatures outside the range of -25…40 °C
(-13…104 °F)

Bearing Load

Atmosphere

Operating
Hours per Day

Standard -18…40

°

C

(-0.4…104

°

F)

Steady Clean 8

Severe -30…50

°

C

(-22…122

°

F)

Medium Shock,
Vibration
less than 0.2 in/s

Medium Dirt,
Abrasives,
Corrosion

8…24

Extreme

(1)

(1)

Extreme service conditions are rare in actual practice. corresponding lubrication cycles should therefore be applied with
caution. In addition, it is advisable to check with Rockwell Automation for special instructions.

-50…65

°

C

(-58…149

°

F)

Heavy Shock,
Vibration
greater than 0.44
in/s

Heavy Dirt,
Abrasives,
Corrosion

8…24

Normal Operating Speed

Lubrication Interval in Months

Max. rpm

Standard Service

Severe Service

Extreme Service

3450 and higher

9

4

1

2400…3449 24

9

3

1700…2399 36

12

3

800…1399 36

24

8

500…799 48 36 12

499 and lower

48

36

12