8 HPK-Series Asynchronous Servo Motors

Publication HPK-IN001C-EN-P - June 2010

Allow sufficient clearances in the area of the motor for it to stay within its specified operating
temperature range. Refer to Specifications for the operating range. Do not install the motor in an
area with restricted airflow. Keep other heat producing devices away from the motor.

Recommended mounting bolts and the torque values are listed below.

Refer to Load Force Capacities to determine the radial and axial shaft load limitations of your
motor.

IMPORTANT

Sufficient clearance must be provided on all inlet and outlet openings to
provide for unrestricted flow of air. Allow at least 152 mm (6.0 in.) of clearance
between the blower exhaust opening and adjacent walls or floor.

Motor Hole

Diameter

Bolt Size
and
Thread

Recommended Torque

Bolt Grade 8.8

Bolt Grade 12.9

HPK-B and HPK-E

mm (in.)

N•m (lbs.)

N•m (lbs.)

1307 12

(0.47)

M10-1.5

8.8 (78)

12.9 (114)

1308 M10-1.5

50

(442)

72

(637)

1310

15 (0.60)

M12-1.75

126 (1115)

158 (1398)

1609 M10-1.75

1611

19 (0.75)

M16-2.5

238 (2106)

337 (2983)

1613

M16-2.5

420 (3717)

596 (5275)

1815

24 (0.95)

M22-2.5

658 (5823)

934 (8266)

2010 M22-2.5

2212

19 (0.75)

M16-2.5

420 (3717)

596 (5275)

2510

21 (0.81)

M20-2.5

495 (4381)

920 (8142)