8 HPK-Series Asynchronous Servo Motors
Publication HPK-IN001C-EN-P - June 2010
Allow sufficient clearances in the area of the motor for it to stay within its specified operating
temperature range. Refer to Specifications for the operating range. Do not install the motor in an
area with restricted airflow. Keep other heat producing devices away from the motor.
Recommended mounting bolts and the torque values are listed below.
Refer to Load Force Capacities to determine the radial and axial shaft load limitations of your
motor.
IMPORTANT
Sufficient clearance must be provided on all inlet and outlet openings to
provide for unrestricted flow of air. Allow at least 152 mm (6.0 in.) of clearance
between the blower exhaust opening and adjacent walls or floor.
Motor Hole
Diameter
Bolt Size
and
Thread
Recommended Torque
Bolt Grade 8.8
Bolt Grade 12.9
HPK-B and HPK-E
mm (in.)
N•m (lbs.)
N•m (lbs.)
1307 12
(0.47)
M10-1.5
8.8 (78)
12.9 (114)
1308 M10-1.5
50
(442)
72
(637)
1310
15 (0.60)
M12-1.75
126 (1115)
158 (1398)
1609 M10-1.75
1611
19 (0.75)
M16-2.5
238 (2106)
337 (2983)
1613
M16-2.5
420 (3717)
596 (5275)
1815
24 (0.95)
M22-2.5
658 (5823)
934 (8266)
2010 M22-2.5
2212
19 (0.75)
M16-2.5
420 (3717)
596 (5275)
2510
21 (0.81)
M20-2.5
495 (4381)
920 (8142)