Pre-Installation Instructions

Installation must be in accordance with the following steps and must be
carried out by competent personnel. The DriveGuard Safe Torque Off option
is intended to be part of the safety related control system of a machine. Before
installation, a risk assessment should be performed that compares the
DriveGuard Safe Torque Off option specifications and all foreseeable
operational and environmental characteristics of the machine to which it is to
be fitted.

In no case should be DriveGuard Safe Torque Off option be used in a
PowerFlex 40P or PowerFlex 70 drive where the maximum surrounding air
temperature, shock, or vibration specifications of the drive are exceeded.

A safety analysis of the machine section controlled by the drive is required to
determine how often the safety function should be tested for proper
operation during the life of the machine.

PowerFlex 70

Maximum Surrounding Air Temperature
without derating:

IP20, NEMA/UL Type 1:
Flange Mount:
IP66, NEMA/UL Type 4X/12:

0…50 °C (32…122 °F)
0…50 °C (32…122 °F)
0…40 °C (32…104 °F)

PowerFlex 40P Maximum Surrounding Air Temperature

without derating:

IP20, Open Type:
IP30, NEMA 1, UL Type 1:
Flange and Plate Mount:

-10…50 °C (14…122 °F)
-10…40 °C (14…104 °F)
Heatsink: -10…40 °C (14…104 °F)
Drive: -10…50 °C (14…122 °F)

Both Drives

Shock:

15 g peak for 11 ms duration (

±1.0 ms)

Vibration:

0.152 mm (0.006 in.) displacement, 1 g peak

ATTENTION: The following information is merely a guide for proper installation.
Rockwell Automation, Inc. cannot assume responsibility for the compliance or the
noncompliance to any code, national, local or otherwise for the proper installation of
this equipment. A hazard of personal injury and/or equipment damage exists if codes
are ignored during installation.