Installation and Wiring

Figure 5 - PowerFlex 70 Safe Torque Off Connection Jumper Location (Typical)

2.

Remove the PowerFlex 70 Hardware Enable jumper as shown in
Figure 6.

Figure 6 - PowerFlex 70 Hardware Enable Jumper Location (Typical)

3.

Plug the DriveGuard Safe Torque Off option (Series A or greater)
into the PowerFlex 70 four pin connector as shown in Figure 7.

IMPORTANT

The PowerFlex 70 hardware enable jumper must be removed when using the
DriveGuard Safe Torque Off option. Failure to remove the jumper will cause the drive
to fault when a start command is issued.