9

Exploring Advanced Topics

139

Tune the database. Understand when to use indices and how to archive
data. Consult your database administrator for assistance.

Optimize queries, triggers, and stored procedures executed by
FactoryTalk Transaction Manager.

FactoryTalk Transaction Manager

Trigger transactions on unscheduled data change instead of scheduled
transaction execution.

If you must use DDE, select hot links instead of cold links to the control
data server.

Use FactoryTalk Device Scheduled collection mode, which improves
data accuracy and reduces network traffic.

This collection mode will cause transactions to run slower.

Distribute both control connectors and enterprise connectors on
multiple computers.

When using real-time transactions, use multiple real-time threads. The
disadvantage is that this consumes extra connections to the database.
Some databases are licensed based on the number of simultaneous
connections.

Use an Oracle OCI connection instead of an ODBC connection to an
Oracle database.

Use cached transaction files instead of real-time threads, which
enhances database performance on commercial databases that allow
―array inserts.‖

Modify the cached transaction file parameters (number of transactions
per log file and time between cache files) to optimize the scheduling and
volume of transactions to your database.

Disable debug error logging in FactoryTalk Transaction Manager.